Aerial view of a Jetour car dealership with a 150 kW rooftop solar system

Commercial solar and batteries, engineered properly

Residential and commercial EPC · Multi-provincial installation · 5 kW to 2.5 MW

  • Sigenergy certified installer
  • Herholdt's Premium Partner
  • PV GreenCard installer
  • Registered electrical contractor

Partners, brands and accreditations

  • Sigenergy certified installer Certified installer
  • Herholdt's Premium Partner Premium Partner
  • PV GreenCard installer
  • Deye
  • Registered electrical contractor
  • Samsung
  • Level 1 B-BBEE
  • Alliance
  • ITS-approved installer
A commercial building with 600 kWp of solar panels on its roof, battery storage (BESS) and a hybrid inverter beside it, a generator and the grid connection.

A day on a 600 kWp commercial site

  1. 05:30

    Before sunrise

    Overnight the grid carries the site's steady 300 kW, and the BESS holds a 70% reserve for the next power cut.

  2. 07:30

    The sun comes up

    The panels start producing. The grid tops up what they can't cover yet.

  3. 10:00

    Solar runs the site

    By mid-morning the panels carry the whole load, and the spare starts charging the BESS.

  4. 12:30

    Midday: nothing wasted

    The roof makes more than the site uses. The spare charges the BESS, and the system is set to zero export, so nothing goes back into the grid.

  5. 16:30

    Charged for the evening

    The BESS is full before the sun goes down, holding the day's spare solar for the evening.

  6. 17:45

    The BESS carries the evening

    As the sun sets, the BESS supplies the site with the solar it stored at midday, then holds its reserve.

  7. 18:30

    Power cut: no break in supply

    The grid goes down. The system separates from it in milliseconds, and the BESS keeps the whole site, or its critical loads, running.

  8. 21:30

    Long outage: the generator takes over

    When the BESS is down to 20%, the system starts your generator. It runs the site and recharges the BESS, then switches off again, so it runs far less.

  9. 23:00

    The grid is back

    The generator stops, the site goes back to the grid, and the BESS recharges to its reserve for the next outage.

  10. 05:30

    Every day, sized to your site

    On an average day this site makes about 2,880 kWh of solar, saving about R11,520 at R4/kWh, or R345,600 a month. We size every system from your own bills or logged load.

When the grid stays off

Two days without the grid

A steady 300 kW load with 600 kWp of solar, a 1,250 kWh BESS and a 650 kVA standby generator. The grid is off for all 48 hours.

  • Generator about 20 hours

    Over two days, in four runs, using about 2,460 litres of diesel. On the generator alone, the site would burn about 4,340 litres.

  • Each run recharges the BESS

    The generator carries the load and recharges the BESS to 80%, leaving room for solar, then stops. It starts again only when the BESS is down to 20%.

  • Solar by day

    From about 09:30 to 14:30 solar carries the whole load and charges the BESS with the rest, so the generator stays off.

An example on an average Highveld day. We size every system from your own site's load.

Charts of a 48-hour grid outage on a site with a steady 300 kW load. Solar carries the load in the middle of each day and charges the battery. The battery carries the load in the evening. When the battery is down to 20%, the generator runs the site and recharges the battery to 80%, then stops: four runs and about 20 hours over the two days.

What we build

Every system is sized from your own load data and designed around your supply, your roof and the way your site runs.

  • 50 kW to 2.5 MW

    Hybrid solar with battery backup

    Batteries (BESS) that carry the whole site, or just the critical loads, through outages, with the switch-over built into the system. Sigenergy and Deye.

    Commercial solar
  • 50 kW and up

    Grid-tie solar

    Daytime generation without batteries, set to zero export and ready for batteries later. Deye or Sigenergy, and Sungrow or Sigenergy above 1 MW.

  • Existing or new generators

    Generator integration

    We connect your generators so the batteries carry the site first and the generator starts only when they run low.

  • 7 to 22 kW chargers

    EV charging

    AC chargers for fleets, staff and visitors, wired, protected and connected to your solar system.

  • ITS-approved installer

    Heat pumps

    ITS heat pumps for hostels, kitchens and change rooms: supply, installation and the annual service.

  • Registered electrical contractor

    Electrical and aircon

    LED retrofits, dedicated circuits, DB upgrades and CoCs, plus aircon and HVAC: installation, servicing, repairs and regassing.

    All services

How a commercial project runs

One team from the first site visit to the last certificate, with the scope and price agreed before we start.

  1. 1Assess

    We start with your numbers

    We go through your bills and, when there's time, log your site's load for about a week with a power analyser, so the system is sized on how your site really runs.

  2. 2Design

    Designed around your load

    Roof layout, yield model and single-line diagram, with a structural check and Pr Eng sign-off where your municipality needs one. We show you the assumptions, and give you options where there is a real choice to make.

  3. 3Build

    Installed to a written standard

    We work to our own installation standard under a site safety file, with our registered Installation Electrician supervising, inspecting and testing.

  4. 4Connect

    Switched on and registered

    Testing, commissioning and zero-export switch-on, then we see your SSEG application through. Systems over 100 kW are registered with NERSA too.

  5. 5Support

    Looked after afterwards

    We set your system up on the manufacturer's monitoring platform and offer maintenance plans to keep it performing.

The equipment we install

Two hybrid platforms for different budgets, designed and installed to the same standard.

  • Sigenergy

    Our premium range, for homes and business

    We're a Sigenergy certified installer. Sigenergy combines solar, batteries and backup in one modular platform, monitored on the Sigen Cloud.

    • Homes: SigenStor and SigenStor Neo, with backup built into Neo
    • Business: 50, 110 and 125 kW hybrids, up to three on one backup supply without a gateway
    • SigenStack plants up to 2.5 MW, with whole-site backup through Sigenergy gateways
    • Grid-tie systems and EV chargers
    Commercial solar
  • Deye

    Our value range, for homes and business

    Deye hybrid inverters and batteries are the heart of our home packages, and of commercial systems where the budget matters most.

    • Homes: single and three-phase hybrid inverters with Deye batteries
    • Business: 50 to 125 kW hybrids, and PCS systems with static transfer switches up to 2.5 MW
    • Grid-tie systems, ready for batteries later
    • Installed to our own written installation standard
    Solar for homes
    Deye SE-F16-C 16 kWh battery and Deye SE-F5 5 kWh battery

Recent work

See our projects
  • Aerial view of a 150 kW rooftop solar system on a commercial building

    Commercial building150 kW rooftop solar

  • Battery storage (BESS) room with stacked battery modules and a control cabinet

    Battery storage (BESS) room

  • Narrow plant room with a high-voltage battery rack, a hybrid inverter and an overhead cable tray

    Plant roomBattery rack, inverter and cable tray

  • Deye battery cabinet with its door open

    Deye battery cabinet

  • Deye high-voltage battery stack and hybrid inverter in a plant room

    Deye high-voltage battery stackWith its hybrid inverter

Businesses we've worked for

  • Toyota
  • Hyundai
  • Limpopo Cash and Carry
  • Selfast
  • Supa Save
  • Sweet Hypermarket
  • Factory Shop
  • Otees Cash and Carry
  • Shop n Save
  • Wood Corner
  • K7
  • KBC
  • ZNS
  • Extreme Painting and Waterproofing
  • L&A Construction
Home hybrid inverter with two Dyness batteries

Solar for your home

The same engineering, sized for a house. Deye and Sigenergy hybrid systems, designed from your electricity bill.

  • Sized from your electricity use, from daytime savings up to about 95% of your energy from solar
  • Designed, supplied and installed by us, so one company answers for all of it
  • Start with one battery and add more later

Tell us about your site

Send us the basics and we'll come back with a budget proposal and a date for a site visit.

What to send us

  1. One or two recent electricity bills, or roughly what you use a month
  2. The size of your supply, in amps or kVA
  3. The site's address or a map pin
  4. Photos of the main DB and the roof, if you have them