Commercial solar and batteries, engineered properly
Residential and commercial EPC · Multi-provincial installation · 5 kW to 2.5 MW
- Sigenergy certified installer
- Herholdt's Premium Partner
- PV GreenCard installer
- Registered electrical contractor
Partners, brands and accreditations
Certified installer
Premium Partner
- ITS-approved installer
A day on a 600Â kWp commercial site
-
05:30
Before sunrise
Overnight the grid carries the site's steady 300Â kW, and the BESS holds a 70% reserve for the next power cut.
-
07:30
The sun comes up
The panels start producing. The grid tops up what they can't cover yet.
-
10:00
Solar runs the site
By mid-morning the panels carry the whole load, and the spare starts charging the BESS.
-
12:30
Midday: nothing wasted
The roof makes more than the site uses. The spare charges the BESS, and the system is set to zero export, so nothing goes back into the grid.
-
16:30
Charged for the evening
The BESS is full before the sun goes down, holding the day's spare solar for the evening.
-
17:45
The BESS carries the evening
As the sun sets, the BESS supplies the site with the solar it stored at midday, then holds its reserve.
-
18:30
Power cut: no break in supply
The grid goes down. The system separates from it in milliseconds, and the BESS keeps the whole site, or its critical loads, running.
-
21:30
Long outage: the generator takes over
When the BESS is down to 20%, the system starts your generator. It runs the site and recharges the BESS, then switches off again, so it runs far less.
-
23:00
The grid is back
The generator stops, the site goes back to the grid, and the BESS recharges to its reserve for the next outage.
-
05:30
Every day, sized to your site
On an average day this site makes about 2,880Â kWh of solar, saving about R11,520 at R4/kWh, or R345,600 a month. We size every system from your own bills or logged load.
When the grid stays off
Two days without the grid
A steady 300Â kW load with 600Â kWp of solar, a 1,250Â kWh BESS and a 650Â kVA standby generator. The grid is off for all 48 hours.
-
Generator about 20 hours
Over two days, in four runs, using about 2,460 litres of diesel. On the generator alone, the site would burn about 4,340 litres.
-
Each run recharges the BESS
The generator carries the load and recharges the BESS to 80%, leaving room for solar, then stops. It starts again only when the BESS is down to 20%.
-
Solar by day
From about 09:30 to 14:30 solar carries the whole load and charges the BESS with the rest, so the generator stays off.
An example on an average Highveld day. We size every system from your own site's load.
Charts of a 48-hour grid outage on a site with a steady 300Â kW load. Solar carries the load in the middle of each day and charges the battery. The battery carries the load in the evening. When the battery is down to 20%, the generator runs the site and recharges the battery to 80%, then stops: four runs and about 20 hours over the two days.
Largest project
Sigenergy hybrid systems at 20 hospitals
Our largest project: Sigenergy hybrid systems with battery energy storage (BESS) at 20 hospitals across South Africa, 2Â MW and 2.5Â MWh in total.
- 2MWInverter power
- 2.5MWhBESS
What we build
Every system is sized from your own load data and designed around your supply, your roof and the way your site runs.
50Â kW to 2.5Â MW
Hybrid solar with battery backup
Batteries (BESS) that carry the whole site, or just the critical loads, through outages, with the switch-over built into the system. Sigenergy and Deye.
Commercial solar50Â kW and up
Grid-tie solar
Daytime generation without batteries, set to zero export and ready for batteries later. Deye or Sigenergy, and Sungrow or Sigenergy above 1Â MW.
Existing or new generators
Generator integration
We connect your generators so the batteries carry the site first and the generator starts only when they run low.
7 to 22Â kW chargers
EV charging
AC chargers for fleets, staff and visitors, wired, protected and connected to your solar system.
ITS-approved installer
Heat pumps
ITS heat pumps for hostels, kitchens and change rooms: supply, installation and the annual service.
Registered electrical contractor
Electrical and aircon
LED retrofits, dedicated circuits, DB upgrades and CoCs, plus aircon and HVAC: installation, servicing, repairs and regassing.
All services
The equipment we install
Two hybrid platforms for different budgets, designed and installed to the same standard.
-
Our premium range, for homes and business
Commercial solarWe're a Sigenergy certified installer. Sigenergy combines solar, batteries and backup in one modular platform, monitored on the Sigen Cloud.
- Homes: SigenStor and SigenStor Neo, with backup built into Neo
- Business: 50, 110 and 125Â kW hybrids, up to three on one backup supply without a gateway
- SigenStack plants up to 2.5Â MW, with whole-site backup through Sigenergy gateways
- Grid-tie systems and EV chargers
-
Our value range, for homes and business
Solar for homesDeye hybrid inverters and batteries are the heart of our home packages, and of commercial systems where the budget matters most.
- Homes: single and three-phase hybrid inverters with Deye batteries
- Business: 50 to 125Â kW hybrids, and PCS systems with static transfer switches up to 2.5Â MW
- Grid-tie systems, ready for batteries later
- Installed to our own written installation standard
Recent work
Commercial building150Â kW rooftop solar
Battery storage (BESS) room
Plant roomBattery rack, inverter and cable tray
Deye battery cabinet
Deye high-voltage battery stackWith its hybrid inverter
Businesses we've worked for
Solar for your home
The same engineering, sized for a house. Deye and Sigenergy hybrid systems, designed from your electricity bill.
- Sized from your electricity use, from daytime savings up to about 95% of your energy from solar
- Designed, supplied and installed by us, so one company answers for all of it
- Start with one battery and add more later
Tell us about your site
Send us the basics and we'll come back with a budget proposal and a date for a site visit.
What to send us
- One or two recent electricity bills, or roughly what you use a month
- The size of your supply, in amps or kVA
- The site's address or a map pin
- Photos of the main DB and the roof, if you have them